P0563-BATTERY VOLTAGE HIGH - ESM

For a complete wiring diagram Refer to Section 8W


  • When Monitored:

    Continuously with the ignition on.

  • Set Condition:

    When the monitored battery voltage rises above 16.0 volts.


Possible Causes
 
CHARGING SYSTEM DTCS
 
VEHICLE WAS JUMP STARTED INCORRECTLY
 
SHIFT LEVER ASSEMBLY
 


Always perform the NAG1 Pre-Diagnostic Troubleshooting procedure before proceeding. (Refer to 21 - TRANSMISSION/TRANSAXLE/AUTOMATIC - NAG1 - STANDARD PROCEDURE)

Theory of Operation


The Shift Lever Assembly monitors ignition voltage. The DTC will set, if the monitored battery voltage rises above 16.0 volts.



Diagnostic Test

1.CHECK FOR CHARGING SYSTEM DTCS


NOTE: This includes any one trip faults.



Are there any Engine Charging System DTCs present?

Yes


No
  • Go To 2

2.VEHICLE WAS JUMP STARTED INCORRECTLY



Was the vehicle jump started by another vehicle?

Yes


No
  • Go To 3

3.SHIFT LEVER ASSEMBLY






Did the P0563-BATTERY VOLTAGE HIGH DTC reset?

Yes


No
  • Test Complete.